Description
Multipoint 10 cylinders timed sequential injection control unit
Tech. Specifications
Supply voltage: Vbatt=10÷16V
Operating temperature: -40÷105°C
Current absorption with the actuators disabled: Imax=0.5A
Current absorption in the standby mode: Istandby <5uA
Actuators managed:
- 10 gas injectors with the following characteristics Imax=6, Vbatt,max=16V
- 2 power outputs for gas solenoid valves
Pmax=25W, Imax=2A (power and maximum current for each output with two outputs enabled)
Pmax=50W, Imax=4A (power and maximum current with just one output enabled)
Sensors managed:
- Gas pressure sensor: AEB025
- MAP sensor: AEB025, the car’s original sensor (to be characterised)
- Level sensor: AEB level sensor, standard sensor 0-90Ohm, non standard sensor
- Reduction gear temperature sensor: AEB sensor, type 369
- Gas temperature sensor: ABE type sensor (4.7kOhm)
- Oxygen sensor reading in voltage: 0-1V, 0-5V, 5-0V, 0.8-1.6V, 2.5-3.5V
Management of AEB119B type switch
Certifications
2006/28/CE
67R-01
110R-00
Package contents
control unit
Gas pressure integrated sensor + MAP
switch with push button
harness
bag of accessories